In balanced pair operation, the two wires carry equal and opposite signals and the destination detects the difference between the two. This is known as differential mode transmission. Noise sources introduce signals into the wires by coupling of electric or magnetic fields and tend to couple to both wires equally. The noise thus produces a common-mode signal which is cancelled at the receiver when the difference signal is taken.
This method starts to fail when the noise source is close to the signal wires; the closer wire will couple with the noise more strongly and the common-mode rejection of the receiver will fail to eliminate it. This problem is especially apparent in telecommunication cables where pairs in the same cable lie next to each other for many miles. One pair can induce crosstalk in another and it is additive along the length of the cable. Twisting the pairs counters this effect as on each half twist the wire nearest to the noise-source is exchanged.
Providing the interfering source remains uniform, or nearly so, over the distance of a single twist, the induced noise will remain common-mode. Differential signaling also reduces electromagnetic radiation from the cable, along with the associated attenuation allowing for greater distance between exchanges.
The twist rate (also called pitch of the twist, usually defined in twists per meter) makes up part of the specification for a given type of cable. Where nearby pairs have equal twist rates, the same conductors of the different pairs may repeatedly lie next to each other, partially undoing the benefits of differential mode. For this reason it is commonly specified that, at least for cables containing small numbers of pairs, the twist rates must differ.[1]
In contrast to FTP (foiled twisted pair) and STP (shielded twisted pair) cabling, UTP (unshielded twisted pair) cable is not surrounded by any shielding. It is the primary wire type for telephone usage and is very common for computer networking, especially as patch cables or temporary network connections due to the high flexibility of the cables.
Unshielded twisted pair (UTP)
UTP cables are found in many Ethernet networks and telephone systems. For indoor telephone applications, UTP is often grouped into sets of 25 pairs according to a standard 25-pair color code originally developed by AT&T. A typical subset of these colors (white/blue, blue/white, white/orange, orange/white) shows up in most UTP cables.
For urban outdoor telephone cables containing hundreds or thousands of pairs, the cable is divided into smaller but identical bundles. Each bundle consists of twisted pairs that have different twist rates. The bundles are in turn twisted together to make up the cable. Pairs having the same twist rate within the cable can still experience some degree of crosstalk. Wire pairs are selected carefully to minimize crosstalk within a large cable.
UTP cable is also the most common cable used in computer networking. Modern Ethernet, the most common data networking standard, utilizes UTP cables. Twisted pair cabling is often used in data networks for short and medium length connections because of its relatively lower costs compared to optical fiber and coaxial cable.
UTP is also finding increasing use in video applications, primarily in security cameras. Many middle to high-end cameras include a UTP output with setscrew terminals. This is made possible by the fact that UTP cable bandwidth has improved to match the baseband oftelevision signals.
While the video recorder most likely still has unbalanced BNC connectors for standard coaxial cable, a balun is used to convert from 100-ohm balanced UTP to 75-ohm unbalanced. A balun can also be used at the camera end for ones without a UTP output. Only one pair is necessary for each video signal.
Cable shielding
Twisted pair cables are often shielded in an attempt to prevent electromagnetic interference. Because the shielding is made of metal, it may also serve as a ground. However, usually a shielded or a screened twisted pair cable has a special grounding wire added called a drain wire.
This shielding can be applied to individual pairs, or to the collection of pairs. When shielding is applied to the collection of pairs, this is referred to as screening. The shielding must be grounded for the shielding to work, and is improved by grounding the drain wire along with the shield.
Shielded twisted pair (STP or STP-A)150 ohm STP shielded twisted pair cable defined by the IBM Cabling System specifications and used with token ring or FDDI networks. This type of shielding protects cable from external EMI from entering or exiting the cable and also protects neighboring pairs from crosstalk.Screened twisted pair (ScTP or F/TP) ScTP cabling offers an overall sheath shield across all of the pairs within the 100 Ohm[3] twisted pair cable. F/TP uses foil shielding instead of a braided screen. This type of shielding protects EMI from entering or exiting the cable.Screened shielded twisted pair (S/STP or S/FTP) S/STP (Screened Shielded Twisted Pair) or S/FTP (Screened Foiled Twisted Pair) cabling offer shielding between the pair sets and an overall sheath shield within the 100 Ohm twisted pair cable. This type of shielding protects EMI from entering or exiting the cable and also protects neighboring pairs from crosstalk.
S/STP cable[4] is both individually shielded (like STP cabling) and also has an outer metal shielding covering the entire group of shielded copper pairs (like S/UTP). This type of cabling offers the best protection from interference from external sources, and also eliminates aliencrosstalk.[4]
Note that different vendors and authors use different terminology (i.e. STP has been used to denote both STP-A, S/STP, and S/UTP).[3]See below for the ISO/IEC attempt to internationally standardise the various designations.
Comparison of some old and new abbreviations, according to ISO/IEC 11801:
Old name | New name | cable screening | pair shielding |
---|---|---|---|
UTP | U/UTP | none | none |
STP | U/FTP | none | foil |
FTP | F/UTP | foil | none |
S-STP | S/FTP | braiding | foil |
S-FTP | SF/UTP | foil, braiding | none |
The code before the slash designates the shielding for the cable itself, while the code after the slash determines
the shielding for the individual pairs:
TP = twisted pairU = unshieldedF = foil shieldingS = braided shielding
Name |
Type |
Bandwidth |
Applications |
Notes |
|
0.4 MHz |
Telephone and modem lines |
Not described in EIA/TIA recommmendations. Unsuitable for modern systems.[5] |
|
|
4 MHz |
Older terminal systems, e.g. IBM 3270 |
Not described in EIA/TIA recommmendations. Unsuitable for modern systems.[5] |
|
UTP |
16 MHz |
10BASE-T and 100BASE-T4Ethernet |
Described in EIA/TIA-568. Unsuitable for speeds above 16 Mbit/s. Now mainly for telephone cables |
|
UTP |
20 MHz |
16 Mbit/s Token Ring |
Not commonly used |
|
UTP |
100 MHz |
100BASE-TX & 1000BASE-TEthernet |
Common in most current LANs |
|
UTP |
100 MHz |
100BASE-TX & 1000BASE-TEthernet |
Enhanced Cat5. Same construction as Cat5, but with better testing standards. |
|
UTP |
250 MHz |
1000BASE-T Ethernet |
Most commonly installed cable in Finland according to the 2002 standard. SFS-EN 50173-1 |
|
|
500 MHz |
ISO/IEC 11801:2002 Amendment 2. |
||
S/FTP |
600 MHz |
Telephone, CCTV, 1000BASE-TXin the same cable. 10GBASE-TEthernet. |
Four pairs, S/FTP (shielded pairs, braid-screened cable). Development complete - ISO/IEC 11801 2nd Ed. |
|
|
1000 MHz |
Telephone, CATV, 1000BASE-TXin the same cable. 10GBASE-TEthernet. |
Four pairs, S/FTP (shielded pairs, braid-screened cable). Development complete - ISO/IEC 11801 2nd Ed. Am. 2. |
Solid core cable vs stranded cable
A solid core cable uses one solid wire per conductor and in a four pair cable there would be a total of eight solid wires. Stranded conductor uses multiple wires wrapped around each other in each conductor and in a four pair with seven strands per conductor cable, there would be a total of 56 wires.
Solid core cable is supposed to be used for permanently installed runs. It is less flexible than stranded cable and is more prone to failure if repeatedly flexed. Stranded cable is used for fly leads at patch panel and for connections from wall-ports to end devices, as it resists cracking of the conductors. Stranded core is generally more expensive than solid core.
Connectors need to be designed differently for solid core than for stranded. Use of a connector with the wrong cable type is likely to lead to unreliable cabling. Plugs designed for solid and stranded core are readily available, and some vendors even offer plugs designed for use with both types. The punch-down blocks on patch-panel and wall port jacks are designed for use with solid core cable.